Eaton EX RT 7 kVA RT LV Specifications
Uninterruptible Power Supply
The Eaton EX RT UPS delivers high-end power protection that is perfect for servers, networking and VoIP, storage, telecom equipment, medical equipment and virtualization environments.
Eaton EX RT 7 kVA RT LV Specifications | |
---|---|
General | |
Topology | On-line double conversion with automatic by-pass |
Configuration | Rackmount/Tower |
Catalog Number | EXRTL7000-XL9UMS |
Catalog Number Bare | |
Style Number | 86508 |
Color | Bezel: Metallic grey, sheetmetal: Charcoal grey |
Rating (VA/Watts) | 7000/4900 |
Dimensions (H x W x D, inches) | 15.48 x 17.49 x 26.25 |
Weight (lbs) | 365 |
Warranty | Two-year factory warranty |
Hot-swappable Power | Yes |
Rail Kit Included | Yes |
Contents (Ships with the following items) |
UPS module I/O Box Battery module Transformer Power Management Software Suite CD Serial Cable DB9/DB9 (2) tower stands (4) stand extenders Battery power cable Battery detection cable Transformer cable (6) rail kits with mounting hardware Safety guide Quickstart guide 4-language user manual |
Electrical Input | |
Connection | Hardwired - see manual for terminal block layout |
Input Voltage Range | 120/156 to 280 Volts |
Nominal Voltage | 208 VAC |
Frequency | 50/60 Hz Autoselect |
Electrical Output | |
Voltages | 200/208 (default) /220/230/240/250 Volts Transformer: 100/120/127 Volts |
Output Receptacles | (8) 5-20R (2) L6-30R Hardwired - see manual for terminal block layout |
Power Factor | 0.7 |
Performance | Permanent output voltage & frequency regulation, superior filtering |
Battery | |
Runtime
(minutes) Load (watts)
Mouseover graph for detailed runtime values
Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.
|
|
Maximum number of extended battery modules (EBM) | 1 |
Battery Management | Weekly battery test, EXB auto recognition, automatic runtime adjustment, protection against deep discharge, Emergency Power Off |
Battery Type | Maintenance-free, sealed Lead-Acid battery |
Half-load Runtime at 0.7 PF (Mins) | |
Full-load Runtime at 0.7 PF (Mins) | |
Hot-swappable Batteries | Yes |
Extended Battery Capability | Yes |
Communications | |
User Interface | 4 LEDS + adjustable, multilingual, 2-line, backlit LCD display |
Communication Ports | (1) Serial RS232, (1) Dry Contact DB9 |
Communications Slot | (1) Slot for Transverse Network Management Card |
Environmental & Standards | |
Standards and Compliance | UL 1778 and CSA 22.2, IEC 62 040-1, IEC 62 040-2, IEC 60950, FCC class A |