Eaton 9E UPS
Uninterruptible Power Supply
9E 20kVA UPS Single Feed Less Batt
9E 20kVA UPS Single Feed Int Batt
9E 30kVA UPS Single Feed Int Batt
9E 40kVA UPS Single Feed Int Batt
9E 40kVA UPS Single Feed Int Batt
9E 60kVA UPS Single Feed Int Batt
More pricing below, click here!
9E UPS 4pg:
The Eaton® 9E UPS delivers superior power protection for everexpanding loads in today's space-constrained data centers. Facilitating a lower total cost of ownership (TCO) through three key features — energy-efficiency, internal batteries and compact footprint — the 9E is an ideal solution for small- to mediumsized data centers and other applications desiring highly reliable power protection.
Applications
- Small to medium data centers
- Corporate
- Telecom
- Healthcare
- Banking
- Industrial
- Education
- Government
Energy-efficient performance lowers operating costs
- Delivers up to 98% efficiency
- Up to 7% more efficient than competitive units
- Qualifies for local utility rebates and incentives
Internal batteries provide maximum runtime
- Delivers up to 21 minutes of runtime
- Pre-wired for easy installation
Compact footprint occupies minimal floor space
- Up to 35% smaller than similar competitive solutions
- Allows dedication of more floor space to revenueproducing equipment
Lowest total cost of ownership
The 9E is the clear choice if you're seeking to maximize your return on investment (ROI). Delivering the lowest TCO of any UPS in its class, the 9E offers a unique blend of energy, space and installation savings. The 9E can decrease your TCO by more than $85,000* over its 12-year lifespan when compared to current competitive offerings.
Energy-efficient design
The 9E is capable of achieving up to a 98% efficiency rating, making it one of the most energy-efficient UPSs in its class — and it still provides maximum load protection. Unlike most highefficiency UPSs, the 9E:
- Provides surge suppression for the load
- Detects the location of faults (utility or load) and takes the appropriate action
- Switches to double-conversion operation in less than 4 ms
The 9E will save more than $71,292 in electricity and cooling costs over the life of the product when compared to a 60 kVA UPS operating at 91% efficiency.
Compact footprint
Smaller than any comparable competitor by up to 35%, the 9E allows you to better utilize floor space for revenue- producing equipment. It also puts money back in your pocket that would otherwise be used to build, maintain and condition space for larger power/support equipment. The ongoing annual maintenance cost for office and data center space in the United States is estimated to be between $90 and $224 per square foot. The savings realized from the 9E's smaller footprint quickly adds up.
9E 2pg IT:
The Eaton® 9E UPS gives IT managers an easy way to manage the power in their data center, without having to worry about cost, space or downtime. Developed specifically for IT managers, the 9E confronts typical data center problems head on. It addresses ROI, energy costs, remote management, and efficiency…giving you more time to focus on other important data center issues.
Applications
- Small-to-medium data centers
- Servers, networks, lighting
- Telecom switches and servers
- Medical imagery equipment
- Banking infrastructure
- Mission critical fabrication equipment
Key features and benefits:
Lower operating costs through energy-efficient performance
- Delivers up to 98% efficiency
- Up to 7% more efficient than competitive units
- Qualifies for local utility rebates and incentives
Maximum runtime through internal batteries
- Delivers up to 21 minutes of runtime
- Internal runtimes: 20 kVA - 21 minutes, 30 kVA - 12 minutes, 40 kVA - 10 minutes, 60 kVA - 5 minutes
Occupy less floor space with a compact footprint
- Up to 35% smaller than similar competitive solutions
- Allows dedication of more floor space to revenue-producing equipment
Installation and warranty
- Reduced installation and wiring costs
- One year parts and labor when Eaton startup plan is purchased with unit
Intelligent Power Manager Software
- Monitor and managed multiple power devices across your network
- Extend the uptime of dual-powered servers with redundancy capabilities
Specifications:
Eaton 93E UPS Specifications | |
---|---|
Product Snapshot | |
Power Rating | 20-60 kVA |
Voltage | 208/220 Vac three phase |
Frequency | 50/60 Hz |
Topology | Double conversion online with Multi-Mode (High efficiency) |
Efficiency | 98% in high efficiency mode |
Configuration | Tower |
Batteries | Internal batteries up to 60 kVA External batteries up to 400 kVA |
Input Characteristics | |
Ratings | 20 kVA/16 kW 30 kVA/24 kW 40 kVA/32 kW 60 kVA/48 kW |
Electrical Input | 208/120V, 4 wire 220/127V, 4 wire |
Voltage Range | +20% / -15% at 208V with 100% load without depleting battery |
Operating Frequency | 50/60 Hz (40 to 72 Hz) |
Power Factor | > 0.99 typical |
Input Current Distortion | 5% THD |
Output Characteristics | |
Voltage | 208/220, 3/4 wire |
Regulation | ±1% static, ±5% dynamic at 100% resistive load change, <20 ms response time |
Battery | |
Battery Type | 9 AH, sealed, lead-acid, maintenance free |
Battery Runtime (100% Load) |
20 kVA - 21 minutes 30 kVA - 12 minutes 40 kVA - 10 minutes 60 kVA - 5 minutes |
Charging Method | ABM or float technology |
EBC Runtimes | |
Internal Runtime (Minutes) | 20 KVA: 21 30 KVA: 12 40 KVA: 12 60 KVA: 6.6 |
Internal & External Runtime (Minutes) | 20 KVA: 138 30 KVA: 84 40 KVA: 128 60 KVA: 77 |
Dimensions and weights (mm/inches) | |
Height | 20-30 KVA: 53.5 in/1360 mm 40-60 KVA: 74.9 in/1880 mm |
Width | 20-30 KVA: 20.9 in/530 mm 40-60 KVA: 23.6 in/600 mm |
Depth | 20-30 KVA: 31.5 in/800 mm 40-60 KVA: 31.5 in/800 mm |
Weight | 20-30 KVA: 1049.4 lbs/ 476 kg 40-60 KVA: 1499.1 lbs/ 680 kg |
General Characteristics | |
Efficiency | Up to 98% on high-efficiency mode Up to 92% on double-conversion |
UPS Bpass | Automatic on overload or UPS failure |
Overload (without Bypass) | 102-110% for 10 minutes 111-125% for 30 seconds >/=126% for 150 milliseconds >/=150% for 40 milliseconds Short circuit conditions: current limit at 2.5x nominal FL current for 60 milliseconds. |
Overload (with Bypass) | 102-110% for 10 minutes 111-125% for 30 seconds >/=126% for 150 milliseconds >/=150% for 40 milliseconds Short circuit conditions: immediate transfer to bypass; then 115% continuous, with transient capability of 20x nominal for 10 milliseconds. |
Overload (on Battery) | 102-110% for 10 minutes 111-125% for 30 seconds >/=125%: current limited at 125% for 30 seconds |
Communications | |
Display | Graphical LCD with blue backlight |
LEDs | (4) LEDs for notice and alarm |
Audible Alarms | Yes |
Communication Ports | (1) RS-232 (1) REPO |
Communication Slots | (2) Mini-slot communication bays (3) Building inputs |
Environmental Characteristics | |
Operating Temperature | 0ºC (32ºF) to +30ºC (86ºF); Batteries recommended max. +25ºC (77ºF) |
Storage Temperature | 25ºC (-13ºF) to +55ºC (131ºF) without batteries +15ºC (59ºF) to +25ºC (77ºF) with batteries |
Relative Humidity | 5-95%, non-condensing |
Audible Noise | <65 dBA at 1 meter (noise less room) typical |
Altitude | < 1500m at +30°C (86ºF) |
Certifications | |
Safety Certifications | UL1778 |
EMI Standards | EN55022/EN55024 |
EMI Compliance | IEC 62040-2 |
Quality | ISO 9001: 2000 and ISO 14001: 1996 |
Marking | UL, cUL |
Documentation:
Download the 9E UPS 4pg Product Brochure (PDF).
Download the 9E 2pg IT Product Brochure (PDF).
Download the Intelligent Power Software Suite Brochure (PDF).
Pricing Notes:
- Pricing and product availability subject to change without notice.
- Contact service for information on kVA upgrade kits.
- External battery cabinet (EBC) can be added at any time, however requires authorized service.
- Eaton recommends you use a left side SAIC-B if Extended battery cabinets (EBC) are to be installed.
- Wall mount bypass are three-breaker type, therefore for dual feed, separate feed will be required to be supplied by others to feed rectifier.
- Mount Transformer or IDC cabinets on the same side as SAIC-B cabinet.
- Maximum of 2 Extended Battery Cabinets can be bought for a system. See runtime chart.
- Distribution breakers for 36 pole panel are Eaton type BAB or QBH.
9E 20kVA UPS Single Feed Less Batt
9E 20kVA UPS Single Feed Int Batt
9E 30kVA UPS Single Feed Int Batt
9E 40kVA UPS Single Feed Int Batt
9E 40kVA UPS Single Feed Int Batt
9E 60kVA UPS Single Feed Int Batt